Washington Dental Waterline Requirements

Testing follows the dental equipment manufacturer's instructions, or quarterly where no instructions exist, with records retained for five years.

Published by LineTabUpdated Sources checked

What the cited provision requires

WAC 246-817-660; this page summarizes the cited provision, not every applicable rule
RequirementDetails
Water quality standardWater used for nonsurgical procedures must meet the EPA regulatory standard of 500 or fewer CFU/mL.
Testing frequencyPer the dental equipment manufacturer's instructions. Where no manufacturer instructions exist, test quarterly.
After plumbing workTest five to ten days after repair or changes to the plumbing system, and again twenty-one to twenty-eight days later.
Sampling methodLines for an operatory or dental unit may be pooled using equal volumes from up to ten lines, with the number documented, or tested individually.
RecordsA log showing dates and the persons conducting testing or maintenance, or reports from an independent testing entity, retained for five years.

Sources: Washington official legislative or administrative source: WAC 246-817-660

Apply the requirement to your practice record

  • List every unit and waterline, with the equipment instructions and required sample schedule.
  • If pooling is permitted, record included lines, equal-volume collection, and the applicable limit on lines per sample.
  • Keep the collector, dates, method, report, treatment, and any corrective-action and retest record together.
  • Review plumbing or equipment changes for additional test triggers, and retain records for the required period.